1MHz & 3MHz Dual Frequency Ultrasonic Beauty Transducer

1MHz & 3MHz Dual Frequency Ultrasonic Beauty Transducer

Details
1 MHz / 3 MHz is this component’s sales name. Its actual measured frequencies are 1.2 MHz / 2.4 MHz, as confirmed by SonerC. A handpiece drawing and circuit notes give us the starting information for your OEM/ODM enquiry.
Category
Ultrasonic Beauty Transducer
 
Send Inquiry
Description
Technical Parameters

Shenzhen Soner Technology Co., Ltd. is one of the leading manufacturers and suppliers of 1mhz & 3mhz dual frequency ultrasonic beauty transducer in China. With abundant experience, we warmly welcome you to wholesale high quality products for sale here from our factory. We also accept customized orders.

 

A dual-frequency component for device integration

The two modes use a single transducer assembly. A device maker sourcing this part will also need to define the circuit that drives it and the mounting inside the handpiece. The supply described here covers the component itself.

Gallery note: The seven images are SonerC beauty transducer series references. An exact-model photograph has not yet been identified.

A section through the proposed handpiece is useful at this stage. It shows the cavity and cable exit alongside the head. Pair it with the circuit notes so the electrical review concerns the same mechanical build.

Specification review for the selected assembly

The table distinguishes the sales name from the actual measured frequencies confirmed by SonerC. The other figures come from the product source sheet. The original test report has not been supplied; measurement conditions and tolerances remain open.

Parameter Confirmed information or source-sheet value Order specification to confirm
Sales frequency designation 1 MHz / 3 MHz Sales name retained for this single dual-frequency product
Actual measured frequencies 1.2 MHz / 2.4 MHz - SonerC-confirmed actual measurements Request the original report, sample reference and test conditions
Frequency tolerance Not established in the available evidence Agree reference frequencies, test conditions and acceptance limits
Bandwidth Source sheet: 23 kHz Separate measured curves, bandwidth definition and which mode the sheet entry describes
Capacitance Source sheet: 3.8 nF Terminal configuration, measurement frequency and tolerance
QM Source sheet: 300 Parameter definition and measurement record for the specified conditions
Ceramic material and diameter Source sheet: 20 mm diameter; material grade to be confirmed Selected ceramic material, specification and assembly drawing
Housing Source sheet: 304 stainless steel; 40 × 6 mm Dimension axes, contact face, mounting features and tolerances
Input power and operating cycle To be agreed for the selected assembly Electrical input definition, driver conditions, power limits and duty cycle
Lead wire Length and construction to be specified Cable specification, exit position and connector pinout
Operating and storage temperature limits To be confirmed Component limits and validation conditions

Electrical information for each mode

In the circuit notes, identify the output available to the head in each mode: voltage, current and any power limit. Include the waveform and intended operating cycle. Impedance curves at both points are needed to assess the match; a reading from one mode leaves the other unexamined.

Also show the mode-change sequence and terminal connections. Any output-off interval during switching belongs in that sequence. If the machine tracks frequency while running, describe the tracking circuit as well.

Installation and application decisions

A new facial-device handpiece

On the section drawing, mark where the head is retained and where its back face sits. Draw in the lead and connector as well; the cable needs room behind the head. Record the intended contact medium and operating cycle for the assembled device. Acoustic output, temperature behaviour and intended-use assessment require evaluation of that device.

Changing an existing single-frequency design

For an upgrade, compare the old head's mounting and electrical data with the proposed two-mode assembly before carrying its fittings or circuit into the new design. Send its drawing and electrical readings. If the design only needs one mode, compare the 1 MHz facial transducer before selecting a dual-frequency build.

Other frequency requirements

For another frequency pair, state the required operating points in the enquiry. A requested 1/3/10/17 MHz four-frequency assembly needs its own development brief. The beauty transducer selection page provides the wider range context.

OEM and ODM project scope

The original product brief covers matching ceramic and metal parts to the host frequency, interface, dimensions, shape and fixing method. Mark the features that must change on your drawing; keep the drawing revision with the electrical requirements.

List OEM part markings, label artwork, packaging and documentation separately. Those requests need confirmation in the supply scope. The same applies to a particular connector, a sensor or a different frequency pair.

The proposed ODM route starts with an agreed drawing and a sample checked against written limits. After approval, freeze that build as the order reference. If a ceramic, metal part or wire specification later changes, identify the revision and check what it affects in the handpiece and delivery plan. The quotation settles quantity, lead times and payment terms.

Manufacturing evidence and acceptance records

The SonerC production equipment page shows the company's ceramic work: pressing, firing, grinding and polarization. Its cleaning-tank and cleaner-assembly sections concern other product lines, rather than proof of this head's production history.

For the selected build, agree which dimensional, electrical, wiring and packing checks will accompany sample acceptance. Keep those records tied to the drawing revision. A general factory photograph cannot supply a batch measurement or establish that a particular inspection was performed.

Buyer questions

Does dual frequency mean two separate transducer heads?

One transducer assembly is listed. Its internal ceramic layout and terminal arrangement still need to be checked against the selected drawing.

Which frequency figures should appear in an integration brief?

Include both, labelled separately as in the table. That lets the enquiry identify the catalogue item while keeping its measured data visible to the engineer. The original report is still needed to document how the readings were taken.

Can the two modes operate simultaneously?

The brief describes switching between modes. Simultaneous output has not been established for this assembly; a design requiring it needs a separate control review.

What measurements are needed for driver matching?

Start with resonance and impedance curves for both modes. Add capacitance readings with the terminal arrangement and measurement frequency, then compare them with the intended circuit and operating cycle.

Does this component specify a treatment depth or HIFU function?

The available component records do not specify either. They provide no evidence for a treatment depth, focused HIFU output or a finished device's cosmetic performance.

Are certificates and individual test reports included?

No supporting certificate or batch report is present in this evidence pack. List the documents your team needs at sample approval and shipment, then have that list included in the agreed supply scope.

Send a dual-frequency integration brief

Send the head drawing or existing-part reference, driver details, operating cycle, cable route and connector. Add the sample checks you require and the intended quantity. Discuss the proposed assembly with SonerC.

 

Hot Tags: 1MHz & 3MHz Dual Frequency Ultrasonic Beauty Transducer, China 1MHz & 3MHz Dual Frequency Ultrasonic Beauty Transducer manufacturers, suppliers, factory, ultrasonic transducer for marine industry, ultrasonic transducer for bluetooth, ultrasonic transducer for ultrasonic detection of radar components, ultrasonic transducer for packaging industry, ultrasonic transducer for ultrasonic scanning, ultrasonic transducer for ultrasonic detection of ultrasonic detection of metal components

Send Inquiry
Contact us if have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!